![]() If you choose to expand the process image area, make the size large enough for the module size plus the default 256 offset. As a solution, either remap the modules to lower offsets within the process image area or expand the process image area to include these modules. ![]() ![]() ![]() That is, data in these modules are inaccessible by some SFCs such as BLKMOV. This is outside of the default process image area size of 128. By default, the SIMATIC software maps the User Data and Result Data Modules to offset 256.In the IO Cycle tab, select the appropriate cyclic update rate for your application.As an alternative, if you wish the PLC to assign an IP address, select the Ethernet button and configure the appropriate address. If your DataMan reader is configured to use its own static IP, uncheck Assign IP address via IO controller.For details, see the SIMATIC Software help. The name must be unique and follow DNS naming conventions. This must match the name of your actual DataMan reader. Right-click the DataMan icon and select Object Properties….You can change the module by deleting the one in the table and inserting the appropriate sized module from the catalog. To optimize performance, use the module size that most closely matches the actual data requirements of your application. There are multiple sizes available for both of these modules. Note: By default, the 64 byte User Data and 64 byte Result Data Modules are inserted.